Selection Table for Cable & Wire - HTK

  • Our Cable & Wire products have been arranged alphanumerically according to product groups
  • The Cable & Wire data sheets underlined in red, you can download directly
  • Alternatively, you can request the relevant data sheets via e-mail or telephone

Product
group

Application

Types

Temperature
ranges

Specification / approvals or standards

EFK/TRO

Data, electronics and control cables suitable for energy guide chains as well as permanently moving cables with strain relief.

EFK-Li9Y11Y

 -30 °C to + 80 °C

UL, CSA,

DESINA, …

EFK-Li9YC11Y

 -30 °C to + 80 °C

TRO-Li9Y11YT11Y

 -30 °C to + 80 °C

TROLi9YC11YT11Y

 -30 °C to + 80 °C

TRO-Li9Y11Y

-40 °C to + 80 °C

FKL

Fluoroplastic insulated data, electronics and control cables

Li6Y

-100 °C to +180 °C

UL, CSA possible

Li6Y6Y

-100 °C to +180 °C

Li6YC6Y

-100 °C to +180 °C

Li7Y

-90 °C to +135 °C

Li51Y

-190 °C to +250 °C

GLS

Fiberglass-insulated data, electronics and control cables

LiGuGfGf

-50 °C to +400 °C

UL, CSA possible

 

LiGuGf-P

-50 °C to +400 °C

LiGuGf

-50 °C to +400 °C

LiNiGlV2A

-60 °C to + 450 °C

HAN

Wiring cables, EVA / EPR-insulated cables, Rubber cables

H07BQ-F

-40 °C to + 80 °C

HAR

HAR

HAR

UL, CSA

H07RN-F

-25 °C to + 60 °C

H07V-K

-30 °C to + 70 °C

Litze UL1015

-30 °C to + 105 °C

HLT

Heating cables

Heating cable

 

 UL, CSA possible

Parallel heating band

 

Heating coil

 

HYB

Hybrid cables

Livz6YC12Y

-40 °C bis +135 °C

UL, CSA possible

Li6YCY

-30 °C bis + 70 °C

LiYCY

-30 °C bis + 80 °C

LiYY…1

-25 °C bis + 70 °C

LiYY…2

-30 °C bis + 80 °C

Motor…1

-40 °C bis + 80 °C

Motor…2

-40 °C bis + 80 °C

Resolver…1

-30 °C bis + 70 °C

SiL

Silicon-insulated data, electronics and control cables

SiF

-60 °C bis +180 °C

 

 

 

 

 

HAR

SiHF

-40 °C bis +180 °C

SiHF-CU-Si

-40 °C bis +180 °C

SiHF-GL-P

-40 °C bis +180 °C

H05SS-F

-50 °C bis +180 °C

SON

Further special cables

LivzY(St)11YV2A

-20 °C bis + 80 °C

UL, CSA possible

LiY-Ylf(St)Y

-40 °C bis +105 °C

Y

-20 °C bis +70 °C

STL

Control cables

YSLY

-40 °C to + 70 °C

 

 

 

UL, CSA possible

YSLYCY

-40 °C to + 70 °C

HSLH

-30 °C to + 70 °C

LiYCY

-30 °C to + 70 °C

LivzYCY

bis 90 °C , (to 125 °C)

Li2YStCYCY

-40 °C to + 80 °C

TAL

Thermal and compensation conductors

Li…Y…Y

 

 

 

IEC, DIN, ANSI, NF, BS

 

DIN IEC 584


We look forward to speaking to you directly!


Click here for further selection tables:

  • Cable & Wire: HTK
  • Heat Shrink Tubing: HTS/HTC
  • Marking System: HTM
  • Protection Sleeves: HTR
  • Electrical Insulation Tubing: HTI
  • Cable Ties: HTB/HTQ